Product Model : | ZCT230M-LBS-BUS-3105 |
Measuring Range : | ±30 ° |
Output : | RS232 |
Power: | Voltage(8~30V) |
Repeatability: | ±0.002° |
Accuracy : | 0.005°-0.01° |
Resolution : | 0.001° |
Application : | Machinery |
IP Degree : | IP66 |
Shell Size : | Φ 84 * 35 mm |
I. General Description
Dual axis up to ±30°, with resolution of 0.001° and accuracy of 0.1°. Incorporating built-in linearity and temperature compensation; both for offset and sensitivity, RS485 output for ease of integration into existing bus systems and easy-to-mount; sealed up to IP66.
II. Features
Entirely industrial device is adopted, with stable performance
Shockproof and anti-vibration
High cost performance
Standard M12 male connector
Technical Specifications ( in room environment @25℃)
3.1 Operation parameter
Parameter |
Test condition |
Min value |
Typical value |
Max value |
Unit |
Supply voltage(1 |
8 |
24 |
30 |
V |
|
Quiescent current |
Supply is 24V |
15 |
20 |
mA |
|
Operating temp |
-40 |
85 |
℃ |
||
Storage tem |
-40 |
125 |
℃ |
3.2 Performance parameter
Measuring range(2 |
2-axis |
-30~30 |
° |
||
Resolution (3 |
Output frequency 3Hz |
0.001 |
0.003 |
° |
|
Repeatability |
Output frequency 3Hz |
±0.03 |
° |
||
Accuracy (4 |
Output frequency 3Hz |
±0.05 |
° |
||
Zero temp drift |
-40~+85℃ |
±0.5 |
±0.86 |
° |
|
Sensitivity temp drift |
-40~+85℃ |
±0.014 |
%/℃ |
||
Cross axis sensitivity |
4 |
% |
3.3 Other parameter
Dimension |
Φ84*35 |
mm |
|||
IP |
IP66 |
Remark 1: when the sensor work normally, make sure it is in the allowable range, 24V is introduced.
Remark 2: the sensor should be installed horizontally.
Remark 3: the smallest angular increment at which a detectable change in output can be measured.
Remark 4: The maximum deviation of the output from the absolute input angle.