Product Model : | ZCT210M-JHY |
Measuring Range : | ±15 ° |
Output : | Switch |
Power: | Voltage(12~36V) |
Accuracy : | 0.001°-0.005° |
Application : | Internet of Things |
IP Degree : | IP65 |
Temperature : | -40℃ ~ +85℃ |
Alarm Angle: | X-axis Y-axis Custom |
1. Measuring range: ±15°.
2. Two-Axis; Alarm angle is defaulted 0.2~0.5 degree..
3. Features: Industrial devices entirely, high stablity and reliable performance; Impact force greater than 10000g; DC 8~36V wide supply vlotage, reverse power protection feture; Relay output; Overload and short circuit protection.
Aluminum shell, protection class IP65
4. Applications: High latitude operating vehicle, elevator; Auto body leveling; Hoist; Automatic positioning platform; Mining machinery, oil drilling equipment; Security control, monitoring, alarm.
1. Operating parameter
Parameter | Test condition | Min value | Typical | Max value | Unit |
Supply vlotage | 8 | 36 | V(DC) | ||
Quiescent current | Without alarm | 20 | 30 | mA | |
Operating temperature range | -40 | +85 | ℃ | ||
Output vlotage① | I=0.5A | VCC-0.5 | VCC | V | |
Output current | 500 | mA |
Remark 1:output vlotage means vlotage drop between singal line and the GND,when the angle reached or excessed the alarm angle.
2. performance specification:
Parameter | Test condition | Min value | Typical value | Max value | Unit |
Measuring range | Two axes | -15 | +15 | ° | |
resolution② | Measuring range≤±15° | 0.003 | ° | ||
accuracy③ | Measuring range≤±15° | ±0.05 | ° | ||
Zero temperature drift | -40~+85℃ | ±0.008 | °/℃ | ||
±0.5 | ±0.86 | ° | |||
Response time④ | 0.5 | s |
Remark 2: resolution means the least variable quantity of measured quantity among the measuring range.
Remark 3: accuracy means the difference between displayed value of the sensor and the true value of the corresponding input .
Remark 4: response time means the the required time for senser output rising to 85% of the output, which is caused by step change of the measured angle.
3.other parameter:
Parameter | Test condition | Min value | Typical value | Max value | Unit |
size | Without mounting plate,cable and fastener | 120*90*38 | mm | ||
Standard cable length | 4.9 | 5 | 5.1 | m |
Wire connection and using instructions:
- Wire connection definition and sketch diagram:
colour | RED | BLACK | BLUE | YELLOW | GREEN | BROWN | WHITE | GREY |
function | Positive of power | GND | Right rear alarm signal | Right front alarm signal | Left front alarm signal | Left rear alarm signal | Zero set | GND |
Installation size: unit:mm